Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
 
- Disconnect the blower motor electrical connector. 
 
- Remove the blower cooling hose.
 
- Remove the screws that secure the motor to the heater/air distribution case.
 
- Remove the motor and the seal from the heater/air distribution case by gently pulling the motor straight down and out.
 
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the blower motor and seal, with the shock mount pads, in the heater/air distribution case. Hold the blower motor in position.
 
- Install the screws to secure the blower motor to the heater/air distribution case.
 
Tighten
Tighten the blower motor retaining screws to 6 N·m (53 lb in).
- Install the blower motor cooling hose.
 
- Connect the electrical connector.
 
- Connect the negative battery cable.
 
- Confirm that the blower motor operates properly.