| Table 1: | Air Delivery Improper | 
This procedure provides a test of all functions of the heater/defroster unit.
Mode Knob  | Temperature Control  | Blower Motor Switch  | Blower Speed  | Power Vent Outlet  | Floor Outlet  | Defrost Outlet  | Side Window Outlet  | 
|---|---|---|---|---|---|---|---|
Vent  | Cold  | OFF  | OFF  | No Airflow  | No Airflow  | No Airflow  | No Airflow  | 
Vent  | Cold  | 4  | High  | Ambient Airflow  | No Airflow  | No Airflow  | No Airflow  | 
Floor  | Cold to Hot  | 4  | High  | No Airflow  | Cold to Hot Airflow  | Minimum Cold to Hot Airflow  | Minimum Cold to Hot Airflow  | 
Defroster  | Cold to Hot  | 4  | High  | No Airflow  | Minimum Cold to Hot Airflow  | Cold to Hot Airflow  | Minimum Cold to Hot Airflow  | 
If any of these settings do not produce the correct results, perform the Improper Air Delivery diagnostic procedure.
Step  | Action  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |||||
2  | Examine the affected door in the unit for proper cable attachment. 
 
 Is everything connected properly?  | Go to Step 4  | Go to Step 3  | ||||
3  | Repair, as necessary. Is the repair complete?  | System OK  | --  | ||||
4  | 
 Does the door move freely through its entire range of travel so that it can close at both ends of the range?  | Go to Step 5  | Go to Step 3  | ||||
5  | Inspect the travel of the Bowden cable by turning the control knob. Is the actuator travel OK?  | Go to Step 6  | Go to Step 7  | ||||
6  | 
 Does the system perform properly?  | System OK  | Go to Step 9  | ||||
7  | 
 Is there a problem with the cable attachment or the control?  | Go to Step 8  | Go to Step 9  | ||||
8  | Repair the cable attachment or control as necessary. Is the repair complete?  | System OK  | Go to Step 9  | ||||
9  | Inspect the system using the Control Settings/Correct Results tests in this procedure. Is the repair complete?  | System OK  | Go to Step 10  | ||||
10  | Inspect for airflow from the defroster or the vent outlets. Is there high airflow from the defroster or the vent outlets?  | Go to Step 11  | Go to Step 12  | ||||
11  | Adjust the heater door at the floor and the vent door to get the proper airflow. Is the repair complete?  | System OK  | --  | ||||
12  | Switch the mode knob to defrost. Is the defroster airflow OK?  | Go to Step 13  | Go to Step 14  | ||||
13  | 
 Is the repair complete?  | System OK  | --  | ||||
14  | Inspect the blower speeds for change in the airflow. Does the blower speed increase as the control is turned from 1 to 4?  | Go to Step 15  | Go to Blower Motor Malfunction  | ||||
15  | 
 Is the repair complete?  | System OK  | Go to Step 16  | ||||
16  | 
 Did the airflow change?  | Go to Step 17  | Go to Step 18  | ||||
17  | 
 Is the repair complete?  | System OK  | --  | ||||
18  | 
 Is the repair complete?  | System OK  | --  |