Removal Procedure
- Remove the front floor console. Refer to 
Front Floor Console Replacement
 .
 
- Remove the selector linkage (2) from the selector lever.
 
| •  | Remove the retaining clamp (1). | 
 
| •  | Disconnect the selector lever from the bracket. | 
 
- Remove the selector lever assembly.
 
| •  | Disconnect the wiring harness plug (1). | 
 
| •  | Remove the 4 bolts (2). | 
 
| •  | Remove the selector lever assembly. | 
 
- Remove the lock control solenoid selector lever lock (2).
 
|     | Important: Note the configuration of cables.
 | 
| •  | Disconnect the 2 wiring plugs (1) from the lock control solenoid. | 
 
| •  | Remove the 2 bolts (3). | 
 
| •  | Remove the lock control solenoid from the selector lever lock. | 
 
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
Important: Note the configuration of cables.
- Install the lock control solenoid for the selector lever lock (2).
 
| •  | Insert the lock control solenoid for the selector lever lock. | 
 
Tighten
Tighten the 2 bolts (3) to 4 N·m (35 lb in).
| •  | Connect the 2 wiring plugs (1) to the lock control solenoid. | 
 
- Install the selector lever assembly.
 
| •  | Insert the selector lever assembly. | 
 
Tighten
Tighten 4 bolts (2) 5 N·m (44 lb in).
| •  | Connect the wiring harness plug (1). | 
 
- Install the selector linkage (2) to the selector lever.
 
| •  | Install the selector lever to the bracket. | 
 
| •  | Install the retaining clamp (1). | 
 
- Install the front floor console. Refer to 
Front Floor Console Replacement
 .
 
- Check the selector lever safety functions. 
 
- For reprogramming procedures, refer to 
Control Module References
.