Special Tools
KM-962-A 
 /KM-962-10 Tester 
Removal Procedure
- Remove the battery.
 
| •  | Disconnect the negative cable (2) from the battery. | 
 
| •  | Disconnect the positive cable (3) from the battery. | 
 
| •  | Remove the bracket (1). | 
 
- Remove the battery support.
 
| •  | Remove the 3 bolts (1). | 
 
- Connect 
KM-962-A 
  (3) to the wiring harness plug of the selector lever position switch
 
| •  | Disconnect the wiring harness plug of the selector lever position switch (1). | 
 
| •  | Open the locking shackle. | 
 
- Connect 
KM-962-A 
 with 
KM-962-A 
 KM-962-10  (2) to the battery.
 
- Inspect the setting of the selector lever position switch.
 
|     | Important: The light diodes corresponding to the markings on the insert module (1) must flash for each individual gear.
 | 
| •  | Shift through all the gears one after the other. | 
 
| •  | If the setting is incorrect: | 
 
|    -  | Inspect the electrical function of the selector lever position switch. | 
 
Installation Procedure
- Connect the selector lever position switch wiring harness plug.
 
| •  | Disconnect 
KM-962-A 
 from the selector lever position switch wiring harness plug. | 
 
| •  | Lock the wiring harness plug. | 
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the battery support.
 
Fasten the cable tie.
Tighten
Tighten 3 bolts 10 N·m (89 lb in).
- Install the battery.
 
| •  | Install the bracket (1). | 
 
Tighten
Tighten bolt 15 N·m (11 lb ft).
| •  | Connect the positive cable (3) to the battery. | 
 
| •  | Connect the negative cable (2) to the battery. | 
 
- For programming procedures, refer to 
Control Module References
.