Removal Procedure
- Recover the refrigerant. Refer to 
Refrigerant Recovery and Recharging
 . 
 
- Remove the block connector, refrigerant lines, from expansion valve. 
 
| 2.2.  | Disconnect the refrigerant lines.  | 
 
Important: If installation is postponed, close off lines and connections. 
- Remove the thermostatically controlled expansion valve (TXV) (1). 
 
Insert the bolt, block connector refrigerant line, in expansion valve (2) and remove the expansion valve. 
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the TXV. 
 
| •  | Use new sealing rings, before installation moisten only green colored sealing rings with mineral oil and insert.  | 
 
| •  | Install the service threaded rods (2) into retaining clip (1) to guide expansion valve.  | 
 
| •  | Push the expansion valve onto service threaded rods until the refrigerant lines lie in the expansion valve.  | 
 
| •  | Replace threaded rods in succession with fixing bolts. | 
 
Tighten
Tighten the expansion valve bolts to 6 N·m (53 lb in).
- Install the block connector. 
 
- Use the new sealing rings, before installation moisten only green colored sealing rings with mineral oil and insert. 
 
Tighten
Tighten the block connector bolt to 7 N·m (62 lb in). 
- Recharge the air conditioning system. Refer to 
Refrigerant Recovery and Recharging
 .