Removal Procedure
- Disconnect the vacuum hoses from the bypass valve actuator.
 
- Remove the bypass valve actuator bolts.
 
- Remove the bypass valve actuator.
 
Installation Procedure
- Install the bypass valve actuator.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the bypass valve actuator bolts.
 
Tighten
Tighten the bolts to 10 N·m (89 lb in).
- Connect the vacuum hoses to the bypass valve actuator.