| Subject: | Service Manual Update to Provide Updated HVAC Tightening Specifications on
the Suction Pipe-to-Compressor Bolt and Discharge Line-to-Compressor Bolt |
| Models: | 2000 Saturn L-Series Sedans and Wagons |
Purpose
The purpose of this bulletin is to provide updated HVAC tightening specifications
that have been revised for the following bolts:
| • | Suction Pipe-to-Compressor Bolt |
| • | Discharge Line-to-Compressor Bolt |
The tightening specification for both bolts listed above has been changed fro
40 N·m (30 lb ft) to 16 N·m (12 lb ft).
All the 2000 L-Series HVAC Service Manuals at your location need to be updated
to reflect the revised tightening specifications.
Obtain all the 2000 L-Series HVAC Service Manuals at your location and update
the above tightening specifications on the following pages:
| • | Page 13 Lines 1 and 5 of the Tightening Specifications table |
| • | Page 90 Tightening Specifications under step 3 |
| • | Page 92 Tightening Specifications under step 7 |
| • | Page 108 Tightening Specifications under step 7 |
| • | Page 110 Tightening Specifications under step 13 |
| • | Page 114 Tightening Specifications under step 9 and 14 |