Diagnostic Instructions
DTC Descriptors
DTC P1A93: 14 Volt Power Module Stuck Off
DTC P1A94: 14 Volt Power Module Stuck On
Circuit/System Description
The starter/generator control module (SGCM) monitors auxiliary power module (APM) On/Off, DC - DC direction is commanded On but converter is Off to check the status of the 14 volt power module. The SGCM also monitors to detect the APM on when
it is not commanded On causing a large current output. If a fault is detected, the appropriate DTC will set.
Conditions for Running the DTC
P1A93, P1A94
The engine is running.
Conditions for Setting the DTC
P1A93
In normal charge mode, 12 volt output voltage - 12-volt command voltage is greater than 0.2-volt for 1 second.
P1A94
DC-DC direction is Off, but converter remains On and APM current is greater than +/-20 amps for 1 second.
Action Taken When the DTC Sets
P1A93, P1A94
• | Stop PWM (MGU shutdown) |
• | Battery disconnection (disconnect SW on/off) |
Conditions for Clearing the DTC
P1A93, P1A94
Clears 30 seconds after cycle wakeup signal.
Diagnostic Aids
P1A93
• | Electrical failure in SGCM, open circuit or open fuse |
P1A94
FET breakdown
Reference Information
Schematic Reference
Hybrid Controls Schematics
Connector End View Reference
Hybrid Controls Connector End Views
Electrical Information Reference
Scan Tool Reference
Scan Tool Data List
Circuit/System Testing
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both
engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using
a DMM before proceeding.
Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect
control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
- If DTC is history, refer to
Testing for Intermittent Conditions and Poor Connections
.
- Gain access to the 12-volt 175-amp SGCM maxi fuse. Refer to
Generator Control Module Cover Replacement
.
- Test for B+ at 175-amp maxi fuse.
⇒ | If less than specified value, test the supply voltage circuit for a short to ground or an open/high restance. |
- Test the 175-amp maxi fuse for an open.
⇒ | If not within the specified range, replace the maxi fuse. |
- If the circuit tests normal, replace the SGCM.
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.
Control Module References
for SGCM replacement, setup, and programming