Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics . Connector End View Reference: Component Connector End Views . DEFINITION: The blower motor operates in at least one, but not all, speed positions.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | 
 Are any blower speeds available?  | Go to Step 4  | Go to Step 3  | 
3  | Check for blown blower motor fuse 9 Was the fuse blown?  | Replace the fuse with the correct amperage fuse.  | Go to Step 4  | 
4  | Check for power at the blower motor. Circuit Testing and Wiring Repairs . Is voltage available, but the blower motor will not operate?  | Replace the blower motor. Refer to Blower Motor Replacement .  | Go to Step 5  | 
5  | 
 Are all blower speeds available?  | Go to Step 9  | Go to Step 6  | 
6  | 
 Were the voltages approximate to the graph?  | Go to Step 9  | Go to Step 7  | 
7  | Connect scan tool. Go to miscellaneous test, switch data. Select all 20 blower fan speeds using the scan tool increase / decrease soft keys Were all speeds available?  | Carry out IRC test for blower switch function.  | Go to Step 8  | 
8  | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you find and correct the condition?  | Go to Step 9  | --  | 
9  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |