Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Deffoger System Check?  | --  | Go to Step 2  | Go to Defogger System Check  | 
2  | 
 Does the test lamp light?  | --  | Go to Step 4  | Go to Step 3  | 
3  | Locate and repair an open in CKT 1440 (ORN) between the HVAC control module connector C1 and the underhood fuse-relay center. Is the repair complete?  | --  | Go to Defogger System Check  | --  | 
4  | Connect a test lampJ 35616-200 from CKT 141 (BRN) at the HVAC control module connector C1 cavity B to ground. Does the test lamp light?  | --  | Go to Step 6  | Go to Step 5  | 
5  | Locate and repair an open in CKT 141 (BRN) between the HVAC control module connector C1 and the I/P fuse block. Is the repair complete?  | --  | Go to Defogger System Check  | --  | 
6  | Connect a test lamp from CKT 141 (BRN) at the HVAC control module connector C2 cavity E to ground. Does the test lamp light?  | --  | Go to Step 8  | Go to Step 7  | 
7  | Locate and repair an open in CKT 141 (BRN) between the HVAC control module connector C2 and S224. Is the repair complete?  | --  | Go to Defogger System Check  | --  | 
8  | Use an ohmmeter in order to probe the HVAC control module connector C1 CKT 1050 (BLK) to ground. Is there continuity?  | --  | Go to Step 9  | Go to Step 10  | 
9  | Replace the HVAC control module. Is the repair complete?  | --  | Go to Defogger System Check  | --  | 