Step 
 | Action 
 | Normal Result(s) 
 | Abnormal Result(s)* 
 | 
1 
 | Start the engine. 
 | 
- The defogger ON indicator is OFF.
 
- The defogger is OFF.
 
 
 | 
 | 
2 
 | 
- Press and release the defogger switch once.
 
- Wait approximately 11 minutes.
 
 
 | 
- The defogger ON indicator turns ON.
 
- The defogger turns ON.
 
- After approximately 10 minutes, both the defogger indicator
and the defogger turns OFF.
 
 
 | 
 | 
3 
 | 
- Press and release the defogger switch once.
 
- Wait approximately 6 minutes.
 
 
 | 
- The defogger ON indicator turns ON.
 
- The defogger turns ON.
 
- After approximately 5  minutes, both the defogger ON indicator
and the defogger turn OFF.
 
 
 | 
 | 
4 
 | 
- Press and release the defogger switch once.
 
- Wait approximately 15 seconds.
 
- Press and release the defogger switch a second time, before a
time-out occurs.
 
 
 | 
- The defogger ON indicator turns ON.
 
- The defogger turns ON.
 
- After the switch is pressed a second time, both the defogger ON
indicator and the defogger turn OFF immediately.
 
 
 | 
 | 
* Refer to the appropriate symptom diagnostic
table for the applicable abnormal  result. 
 |