The number below refers to the step number on the diagnostic table.
Step  | Action  | Values  | Yes  | No  | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation.  | ||||||||||||||
1  | 
 Important: Both the left and the right air temperature controls are diagnosed in this table. Did you perform the Diagnostic System Check - Vehicle?  | --  | Go to Step 2  | |||||||||||
2  | 
 Does the scan tool display any DTC B0408, B0409, B0414, B0418, B0419, or B0424?  | --  | Go to Step 3  | |||||||||||
3  | 
 Does the blower motor operate in any of the speed positions?  | --  | Go to Step 4  | Go to Blower Motor Inoperative  | ||||||||||
4  | Does the blower motor operate in each speed position?  | --  | Go to Step 5  | Go to Blower Motor Malfunction  | ||||||||||
5  | Does the Too Hot in Vehicle concern occur when A/C cooling is desired?  | --  | Go to Step 6  | Go to Step 8  | ||||||||||
6  | 
 IMPORTANT:: For A/C compressor operation, the ambient air temperature must be above 3°C (38°F). 
 Does the A/C compressor operate?  | --  | Go to Step 7  | |||||||||||
7  | Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 8  | ||||||||||
8  | 
 Does the scan tool indicate the driver and passenger temp data values are within the specified parameter?  | 0-255 Counts  | Go to Step 9  | Go to Step 10  | ||||||||||
9  | Inspect the air temperature door and the air temperature actuator for the following conditions: 
 
 
 
 
 Did you find and correct the condition?  | --  | Go to Step 18  | Go to Testing for Intermittent Conditions and Poor Connections  | ||||||||||
10  | Test the door control circuit of the air temperature actuator for the following conditions: 
 
 
 
 Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 11  | ||||||||||
11  | Test the ground circuit of the air temperature actuator for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 12  | ||||||||||
| 
 Important: Ensure that the HVAC control module connector is connected during this step in order to avoid misdiagnosis. 
 Is the voltage within the specified values with a smooth transition between cold and hot?  | 0 V at cold 12 V at hot  | Go to Step 13  | Go to Step 15  | |||||||||||
13  | Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 14  | ||||||||||
14  | Inspect the air temperature door and the air temperature actuator for the following conditions: 
 
 
 
 
 Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 16  | ||||||||||
15  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 17  | ||||||||||
16  | Replace the air temperature actuator. Refer to Temperature Valve Actuator Replacement - Right Side or Temperature Valve Actuator Replacement - Left Side . Did you complete the replacement?  | --  | Go to Step 18  | --  | ||||||||||
17  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | --  | Go to Step 18  | --  | ||||||||||
18  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 2  | ||||||||||