Circuit  | Short to Ground  | Open/High Resistance  | Short to Voltage  | Signal Performance  | 
|---|---|---|---|---|
Vacuum Pump Ignition  | 1  | 1  | --  | --  | 
Vacuum Pump Ground  | --  | 1  | 1  | --  | 
1. Air Delivery Improper  | ||||
The HVAC control assembly uses vacuum to control the mode doors. Vehicles equipped with diesel engines use a vacuum pump to create vacuum. The vacuum pump has ignition voltage circuit and a ground circuit to operate. The pump turns on when vacuum is low and turns off when vacuum reaches 21 Hg.
Control Module References for scan tool information
| ⇒ | If the blower motor speed does not change or fails to operate at a selected speed, refer to Blower Motor Malfunction . | 
| ⇒ | If the air flow fails to blow through the selected outlets, refer to Vacuum Control System Diagnostic . | 
| ⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. | 
| ⇒ | If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. | 