| Table 1: | A/C Performance Table | 
The following test measures the A/C system operating efficiency by comparing:
| • | The ambient air temperature | 
| • | The ambient air humidity | 
| • | The pressure at the high-pressure side of the A/C refrigeration system | 
| • | The pressure at the low-pressure side of the A/C refrigeration system | 
| • | The temperature of the air being discharged into the passenger compartment | 
The number(s) below refer to the step number(s) on the diagnostic table.
This step determines if there is enough refrigerant in the A/C system in order to operate the A/C system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step  | Action  | Value(s)  | Yes  | No  | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 
 Important: 
  | ||||||||||||||||||||||||
 Are both the low and high side pressures within the specified value?  | Above 16°C (60°F) - 345 kPa (50 psi) Above 24°C (75°F) - 483 kPa (70 psi) Above 33°C (90°F) - 690 kPa (100 psi)  | Go to Step 2  | Go to Leak Testing  | |||||||||||||||||||||
 Important: Record the relative humidity and the ambient air temperature AT THE TIME OF THE TEST. 
 
 
 
 
 
 
 Important: When performing this step it is necessary to press the RESET button on the J 43600 before pressing the PRINT button after the 5 minute operating time. 
 
 
 Does all the data recorded fall within the specified ranges of the table below?  | --  | Go to Step 8  | Go to Step 3  | |||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges: 
 Does all the data recorded fall within the specified ranges of the table below?  | --  | Go to Step 8  | Go to Step 4  | |||||||||||||||||||||
4  | Do the high and low side pressures fall within the specified ranges but the outlet temperatures do not?  | --  | Go to Step 5  | |||||||||||||||||||||
5  | Is the low side pressure higher than the specified range and the high side pressure within or lower than the specified range?  | --  | Go to Step 6  | |||||||||||||||||||||
6  | Are the low and high side pressures both higher than the specified ranges?  | --  | Go to Step 7  | |||||||||||||||||||||
7  | Is the low side pressure within or lower than the specified range and the high side pressure higher than the specified range?  | --  | Go to Step 8  | |||||||||||||||||||||
8  | Operate the A/C system in order to verify the test results. Did you find the same results?  | --  | System OK  | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic in HVAC Systems - Automatic  | ||||||||||||||||||||
Ambient Air Temperature  | Relative Humidity  | Service Port Pressure  | Maximum Left Center Discharge Air Temperature  | |
|---|---|---|---|---|
Low Side  | High Side  | |||
13-18°C (55-65°F)  | 0-100%  | 175-243 kPa (25.4-35.3 psi)  | 640-990 kPa (93-143.7 psi)  | 12°C (53.6°F)  | 
19-24°C (66-75°F)  | Below 40%  | 175-256 kPa (25.4-37.2 psi)  | 750-1120 kPa (109-162.6 psi)  | 12°C (53.6°F)  | 
Above 40%  | 184-287 kPa (26.7-41.7 psi)  | 820-1240 kPa (119-180 psi)  | 15°C (59°F)  | |
25-29°C (76-85°F)  | Below 35%  | 196-277 kPa (28.4-40.2 psi)  | 960-1280 kPa (139.3-185.8 psi)  | 14°C (57.2°F)  | 
35-60%  | 212-290 kPa (30.8-42.1 psi)  | 1020-1340 kPa (148-194.5 psi)  | 16°C (60.8°F)  | |
Above 60%  | 223-316 kPa (32.4-46 psi)  | 1070-1460 kPa (155.3-212 psi)  | 18°C (64.4°F)  | |
30-35°C (86-95°F)  | Below 30%  | 220-303 kPa (32-44 psi)  | 1130-1480 kPa (164-214.8 psi)  | 17°C (62.6°F)  | 
30-50%  | 223-322 kPa (33.8-46.7 psi)  | 1190-1570 kPa (172.7-228 psi)  | 19°C (66.2°F)  | |
Above 50%  | 250-350 kPa (36.3-50.8 psi)  | 1260-1710 kPa (183-248.2 psi)  | 21°C (69.8°F)  | |
36-41°C (96-105°F)  | Below 20%  | 245-324 kPa (35.6-47 psi)  | 1300-1630 kPa (188.7-236.6 psi)  | 19°C (66.2°F)  | 
20-40%  | 254-344 kPa (36.9-50 psi)  | 1350-1750 kPa (196-254 psi)  | 21°C (69.8°F)  | |
Above 40%  | 273-364 kPa (39.6-52.8 psi)  | 1440-1860 kPa (209-270 psi)  | 23°C (73.4°F)  | |
42-46°C (106-115°F)  | Below 20%  | 273-348 kPa (39.6-50.5 psi)  | 1440-1860 kPa (209-270 psi)  | 22°C (71.6°F)  | 
Above 20%  | 284-370 kPa (41.2-53.7 psi)  | 1550-1930 kPa (217.7-261.2 psi)  | 24°C (75.2°F)  | |
47-49°C (116-120°F)  | Below 30%  | 308-374 kPa (44.7-54.3 psi)  | 1720-1970 kPa (249.6-286 psi)  | 24°C (75.2°F)  |