Step  | Action  | Yes  | No  | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
1  | Were you sent here from the A/C System Performance Test?  | ||||||||||
2  | After continued operation of the A/C system, do the low and high side pressures equalize or become static?  | ||||||||||
3  | Refer to the pressures recorded during the A/C System Performance Test. Inspect for the following conditions: Caution: Refer to Moving Parts and Hot Surfaces Caution in the Preface section. 
 
 
 
 Do the listed conditions exist?  | ||||||||||
4  | Refer to the pressures recorded during the A/C System Performance Test. Inspect for the following conditions: Caution: Refer to Moving Parts and Hot Surfaces Caution in the Preface section. 
 
 
 
 Do the listed conditions exist ?  | ||||||||||
5  | The A/C system has a low refrigerant charge. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging . Is the procedure complete?  | --  | |||||||||
6  | 
 Are the readings within the specified ranges?  | ||||||||||
7  | The A/C compressor is malfunctioning. Remove the expansion device and inspect for contamination. Refer to Expansion (Orifice) Tube Replacement . Are there metal flakes on the expansion device?  | ||||||||||
8  | Inspect the expansion device for a brown, powdery residue indicating desiccant in the A/C system. Is there a brown, powdery residue present?  | ||||||||||
9  | 
 Is there metal flake contamination present?  | ||||||||||
10  | 
 Is the repair complete?  | --  | |||||||||
11  | 
 Is the repair complete?  | --  | |||||||||
12  | 
 Is the repair complete?  | --  | |||||||||
13  | Operate the system in order to verify the repair Did you correct the condition?  | System OK  | Go to Symptoms - HVAC Systems - Manual OR  |