The numbers below refer to the step numbers on the diagnostic table.
Step  | Action  | Value  | Yes  | No  | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets.  | ||||||||||||||
1  | Did you perform the Diagnostic System Check - Vehicle?  | --  | Go to Step 2  | |||||||||||
2  | 
 Is the blower motor OFF?  | --  | Go to Step 3  | Go to Blower Motor Always On  | ||||||||||
3  | Place the blower motor switch in each speed position. Does the blower motor operate in any speed position?  | --  | Go to Step 4  | Go to Blower Motor Inoperative  | ||||||||||
4  | Does the blower motor operate in each speed position?  | --  | Go to Step 5  | Go to Blower Motor Malfunction  | ||||||||||
5  | Are all of the HVAC control module controls except for the blower motor inoperative?  | --  | Go to Step 14  | Go to Step 6  | ||||||||||
6  | 
 Does the recirculation door move from the recirculation to the outside air position?  | --  | Go to Step 7  | |||||||||||
7  | 
 Does air flow sufficiently from the proper air distribution outlets for each selected mode position?  | --  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 8  | ||||||||||
8  | Inspect the air delivery system for the following conditions: 
 
 
 
 Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 9  | ||||||||||
9  | Inspect the mode door and the mode actuator for the following conditions: 
 
 
 
 
 Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 10  | ||||||||||
10  | 
 Does the test lamp illuminate?  | --  | Go to Step 11  | Go to Step 20  | ||||||||||
11  | Test the ground circuit of the mode actuator for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 12  | ||||||||||
 Does the voltage measure near the specified values for each mode position?  | Vent: 0.2V, Bi-Level: 3.1V, Floor: 5.0V Mix-Blend: 8.9V, Defrost: 11.8V  | Go to Step 18  | Go to Step 13  | |||||||||||
13  | Test the mode door control circuit of the mode actuator for an open, a high resistance, a short to ground, or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | ---  | Go to Step 23  | Go to Step 19  | ||||||||||
Test the ignition 3 voltage circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 15  | |||||||||||
15  | Test the battery positive voltage circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 16  | ||||||||||
16  | Test the ground circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 17  | ||||||||||
17  | Test the off blower motor control circuit of the HVAC control module for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 19  | ||||||||||
18  | Inspect for bad connections at the harness connector of the mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 21  | ||||||||||
19  | Inspect for bad connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 23  | Go to Step 22  | ||||||||||
20  | Repair the ignition 3 voltage circuit of the mode actuator. Refer to Wiring Repairs . Did you complete the repair?  | --  | Go to Step 23  | --  | ||||||||||
21  | Replace the mode actuator. Refer to Mode Actuator Replacement . Did you complete the replacement?  | --  | Go to Step 23  | --  | ||||||||||
22  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | --  | Go to Step 23  | --  | ||||||||||
23  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 8  | ||||||||||