Step  | Action  | Values  | Yes  | No  | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation.  | ||||||||||||||
1  | Did you perform the Diagnostic System Check - Vehicle?  | --  | Go to Step 2  | |||||||||||
2  | 
 Does the blower motor operate in any of the speed positions?  | --  | Go to Step 3  | Go to Blower Motor Inoperative  | ||||||||||
3  | Does the blower motor operate at the desired speeds?  | --  | Go to Step 4  | Go to Blower Motor Malfunction  | ||||||||||
4  | When the A/C is ON, does the customer concern occur?  | --  | Go to Step 5  | Go to Step 7  | ||||||||||
5  | 
 Does the recirculation door move to the recirculation position?  | --  | Go to Step 6  | Go to Air Delivery Improper  | ||||||||||
6  | 
 Does the A/C compressor operate?  | --  | Go to Step 7  | |||||||||||
7  | Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 8  | ||||||||||
8  | 
 Does the air temperature actuator drive shaft rotate at all?  | --  | Go to Step 9  | Go to Step 10  | ||||||||||
9  | Inspect the air temperature door and the air temperature actuator for the following conditions: 
 
 
 
 
 Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 10  | ||||||||||
10  | Test the control A and control B circuits of the air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 11  | ||||||||||
11  | 
 Does the test lamp illuminate with each command?  | --  | Go to Step 14  | Go to Step 12  | ||||||||||
12  | Test the ignition 3 voltage circuit of the HVAC control module for an open, high resistance, or a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 13  | ||||||||||
13  | Test the ground circuit of the HVAC control module for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 15  | ||||||||||
14  | Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 16  | ||||||||||
15  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 18  | Go to Step 17  | ||||||||||
16  | Replace the air temperature actuator. Refer to Temperature Valve Actuator Replacement . Did you complete the replacement?  | --  | Go to Step 18  | --  | ||||||||||
17  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | --  | Go to Step 18  | --  | ||||||||||
18  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 2  | ||||||||||